713 lines
; In the modem list below, MNP5 should be read as a synonym for "Error
; Correction with compression", and MNP4 as a synonym for "Error correction
; with compression disabled", i.e. these names are used even if the modem
; really uses V42/V42bis. This shorthand is used because anything else turns
; out to be incredibly long winded.
; The modem list only gives strings where they differ from INSTALL defaults.
; The default modem is 2400, no error correction, no init required, generic
; Hayes compatible. MNP in software.
------------------------
<Direct Connect / Null Modem>
------------------------
Generic Slow Modem (2400 bps and below)
Init = ATQ0V1E1X1S0=0|
------------------------
Generic Fast Modem (9600 bps and above)
Init = ATQ0V1E1X1S0=0&C1&D2|
Speed = 38400
Hardware MNP
------------------------
Acex 2400 V22bis+MNP5
Init = ATQ0V1E1X1S0=0&D2&C1\J0\Q3\V1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Amber Logic Mistral FX24s
Init = ATS7=55S0=0|
Speed = 2400
Disable EC = AT&E0|
Set MNP4 = AT&E1%C0|
Set MNP5 = AT&E5%C1|
Hardware MNP
------------------------
Amstrad SM4000/MC2400
Init = ATQ0V1E1X2S0=0F0&D2&C1|
------------------------
ATI Technologies, Inc. 2400etc
Init = ATB1E1L1M1N1TQ0V1W1X6&Q5&B1&C1&D2&K3&O1|
Speed = 9600
Disable EC = AT&Q0W0&B0&K0&O0|
Set MNP5 = AT&Q5W1&B1&K3&O1|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER|VOICE
Hardware MNP
------------------------
Best Data 2400B/2400X
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Best Data 9624F/FX FAX Modem
Init = ATB1E1Q0V1X4&C1&D2&M0|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Best Data Smart One 1442F/FX FAX Modem
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 38400
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136\N3W1&K3|
Set MNP5 = AT&Q5S46=138\N3W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Best Data Smart One 9624FQ FAX Modem
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Boca Research BOCAFAX
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Boca BOCAMODEM M1440EW/M1440IW
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 38400
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136\N3W1&K3|
Set MNP5 = AT&Q5S46=138\N3W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Boca BOCAMODEM M2400E/M2400I
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 9600
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136W1&K3|
Set MNP5 = AT&Q5S46=138W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Boca BOCAMODEM PM1440
Init = ATB1E1Q0V1W1X4&Q5S46=138&C1&D2&K3\N3|
Speed = 38400
Disable EC = AT&Q6W0&K0|
Set MNP4 = AT&Q5S46=136\N3W1&K3|
Set MNP5 = AT&Q5S46=138\N3W1&K3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Boca Pocket Modem 96/24
Init = ATB1E1Q0V1X4&C1&D2&Q0|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
British Telecom PC424X
Init = AT&FS0=0&D3&W|
Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
Hangup =
Dial Delay = 2
------------------------
Compucom Speedmodem (9600)
Init = AT&FX4E1Q0V1&C1&D2S0=0|
Speed = 19200
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Cray Quattro 144
Init = ATE1F0M1Q0V1X4&C1&D2&E1&I1&K2&Q0&U2%C1/Q1/S1/U0"U0S0=0|
Speed = 38400
Disable EC = AT&E0|
Set MNP4 = AT&E1%C0|
Set MNP5 = AT&E1%C1|
Hardware MNP
------------------------
Dacom Datamate
Init = ATQ0V1E1X4S0=0&D2&C1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT\N3%C0|
Set MNP5 = AT\N3%C1|
Hardware MNP
------------------------
Dacom DSL2123 (DTI)
Init = |NP|~RESET|
Speed = 1200
Tone Dial = V23T|~TON|
Pulse Dial = V23T|~PLS|
Dial Suffix = |
Connect = &WAT
AutoAnswerOn = |NP|~AA|
AutoAnswerOff= |NP|~RESET|
------------------------
Dacom Quadplus
Init = ATQ0V1E1X4S0=0&D2&C1F1\J1&B0\Q2\T0B0\X2|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = ATS34=4\N3|
Set MNP5 = ATS34=5\N3|
Hardware MNP
------------------------
Dataflex Pocket Stradcom
Init = ATQ0V1E1X1S0=0|
------------------------
Dataflex Quadcom V22bis
Init = ATQ0V1E1X4S0=0&D2&C1\J0\Q3\V0S7=55|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Dataflex Quadcom 2400 + FAX
Init = ATQ0V1E1X4S0=0&D2&C1|
Speed = 4800
Disable EC = AT&Q0|
Set MNP4 = AT%C0&Q3|
Set MNP5 = AT%C1&Q3|
Hardware MNP
------------------------
Dataflex PC Rapier +
Init = AT&FS7=180S0=0|
Speed = 19200
Disable EC = AT\N0%C0|
Set MNP4 = AT\N3%C0|
Set MNP5 = AT\N3%C3|
Hardware MNP
------------------------
Datatronics Discovery 2400c
Init = ATX4E1Q0V1S0=0|
Speed = 2400
------------------------
Datatronics Discovery 2400 (MNP)
Init = ATX4E1Q0V1&C1&D2S0=0B0\J0\G0\Q3\V1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT\N3%C0|
Set MNP5 = AT\N3%C1|
Hardware MNP
------------------------
Datronics Discovery 9600
Init = ATQ0E1V1X1S7=255|
Speed = 19200
Disable EC = AT\Z|
Set MNP4 = AT%C0\Y|
Set MNP5 = AT%C1\Y|
Hardware MNP
------------------------
Dowty Quattro
Init = ATQ0V1E1X3S0=0F0&D2&C1&A0&I0|
Disable EC = AT&E0|
Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|BLACKLISTED|ERROR
Hangup =
------------------------
Dowty/Telebit Trailblazer
Init = ATQ0E1V1X3S7=60S110=1|
Disable EC = ATS95=0|
Set MNP4 = ATS95=2|
Set MNP5 = ATS95=2|
Hardware MNP
------------------------
Dynalink FAX Modem 2400
Init = ATQ0V1E1X4S0=0|
------------------------
E-Tech BulletModem PC1414MX/DX
Init = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
Speed = 38400
Disable EC = AT$E0$F5$X0|
Set MNP4 = AT$E3$F4$C0$X2|
Set MNP5 = AT$E3$F4$C1$X2|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
E-Tech UFOMATE P1414MX/DX
Init = ATB1E1Q0V1X4&C1&D2&L0$E3$F4$C1$X2|
Speed = 38400
Disable EC = AT$E0$F5$X0|
Set MNP4 = AT$E3$F4$C0$X2|
Set MNP5 = AT$E3$F4$C1$X2|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Gandalf ACCESS Series 3242
Init = AT&FX4E1Q0V1&C1&D2\J0\Q3\V0S0=0|
Speed = 19200
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
GVC Technologies FAX Modem 9648
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
GVC Technologies Super Modem 2400
Init = ATB1E1Q0V1X4&C1&D2&M0|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Hayes Generic
Init = ATQ0V1E1X1S0=0|
------------------------
Hayes V-Series 2400 Quadplus
Init = ATX4E1Q0V1&C1&D2S0=0&K1W2|
Disable EC = AT&Q0|
------------------------
Hayes V-Series ULTRA Smartmodem 9600
Init = ATX4E1Q0V1&C1&D2S0=0&K3W2|
Speed = 38400
Disable EC = AT&Q0|
Set MNP4 = ATS46=0&Q5|
Set MNP5 = ATS46=2&Q5|
Hardware MNP
------------------------
Hitec EC2400
Init = ATE1Q1V1S0=0X4F0&D2&C1&I1B0&S0\Q2|
Speed = 4800
Disable EC = AT\N1|
Set MNP4 = AT%C0\N2|
Set MNP5 = AT%C1\N2|
Hardware MNP
------------------------
Hyundai HMD-2404M
Init = ATE1Q1V1S0=0X4\J0\Q3&D2&C1B0|
Speed = 9600
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Intel 2400/2400e V.42bis Modem
Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
Speed = 9600
Disable EC = AT\N0\V1\Q0\C1|
Set MNP4 = AT\N3\V2\Q3\J0\C1%C0"H0|
Set MNP5 = AT\N3\V2\Q3\J0\C1%C1"H3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Intel SatisFAXtion Modem/100
Init = ATB1E1Q0V1X4&C1&D2|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Intel SatisFAXtion Modem/200
Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
Speed = 9600
Disable EC = AT\N0\V1\Q0\C1|
Set MNP4 = AT\N3\V2\Q3\J0\C1%C0"H0|
Set MNP5 = AT\N3\V2\Q3\J0\C1%C1"H3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Intel SatisFAXtion Modem/300
Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3%C1"H3|
Speed = 38400
Disable EC = AT\N0\V1\Q0|
Set MNP4 = AT\N3\V2\Q3%C0"H0|
Set MNP5 = AT\N3\V2\Q3%C1"H3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Intel SatisFAXtion Modem/400 /400e
Init = ATB1E1Q0V1X4&C1&D2\N3\V2\Q3\J0\C1%C1"H3|
Speed = 38400
Disable EC = AT\N0\V1\Q0\C1|
Set MNP4 = AT\N3\V2\Q3\J0\C1%C0"H0|
Set MNP5 = AT\N3\V2\Q3\J0\C1%C1"H3|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Kerridge (KNS) Micro Quad
Init = ATV1X4&C1&D2&K2&E4S0=0|
Speed = 4800
Disable EC = AT&E0|
Set MNP4 = AT&E8|
Set MNP5 = AT&E4|
Failure = ERROR|BUSY|NO CARRIER|NO DIALTONE|LINK FAILURE|BLACKLISTED
Hardware MNP
------------------------
Kerridge (KNS) Micro Quin (V32)
Init = ATV1X4&C1&D2&K2&E4S0=0|
Speed = 19200
Disable EC = AT&E0|
Set MNP4 = AT&E8|
Set MNP5 = AT&E4|
Failure = ERROR|BUSY|NO CARRIER|NO DIALTONE|LINK FAILURE|BLACKLISTED
Hardware MNP
------------------------
Mayze 24
Init = ATV1X6Q0&Q0&C1&D2"U13*M0F0&G2%K2%U2&I1|
Speed = 9600
Disable EC = AT-E0|
Set MNP 4 = AT-E1%C0|
Set MNP 5 = AT-E1%C1|
Hardware MNP
------------------------
Mayze 96
Init = ATX4E1Q0V1&C1&D2S0=0&Q6%K2%U2"U20|
Speed = 38400
Disable EC = AT-E0|
Set MNP4 = AT%C0-E1|
Set MNP5 = AT%C1-E1|
Hardware MNP
------------------------
Microcom/Tricom AX2410c
Init = ATE1Q0V1S0=0X3&D2&C1&S1\D3\Q3\R1M1\J0\X1\V1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Microcom/Tricom Tornado 10/42
Init = ATX4E1Q0V1&C1&D2S0=0|~~AT\X1%G1\J0-M1\V2\G0\Q3|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C3\N3|
Hardware MNP
------------------------
Microcom/Tricom Tornado Quin 42
Init = ATX4E1Q0V1&C1&D2S0=0%E1%G0\J0%L1\Q3|
Speed = 9600
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Microcom/Tricom PC Quad
Init = ATQ0V1E1X1&C1&D2&G2S7=60|
Speed = 38400
Disable EC = AT\Z|
Set MNP4 = AT%C0\Y|
Set MNP5 = AT%C1\Y|
Hardware MNP
------------------------
Microlin FX 32 Plus
Init = ATQ0V1E1X1&C1&D2S0=0|
Speed = 38400
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C3\N3|
Hardware MNP
------------------------
Microlink modem
Init = AT&FQ0V1E1X1S0=0S50=1S57=0|
------------------------
Miracom WS3000/WS4000
Init = |~~ATZ|~~~ATQ0V1E1X1S0=0S7=59S9=6S10=25S22=0S31=0|
------------------------
Miracom WS3000 MK2 MNP5
Init = |~~ATZ|~~~ATQ0V1E1X1S0=0S22=0&I2&C1&D2|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT\N2%C0|
Set MNP5 = AT\N2%C1|
Hardware MNP
------------------------
Multitech 224EH
Init = ATQ0V1E1S0=0&E4|
Speed = 4800
Disable EC = AT&E0|
Set MNP4 = AT&E14&E2|
Set MNP5 = AT&E15&E2|
Hardware MNP
------------------------
Multitech Multimodem V32
Init = ATQ0V1E1S0=0&E4|
Speed = 19200
Disable EC = AT&E0|
Set MNP4 = AT&E14&E2|
Set MNP5 = AT&E15&E2|
Hardware MNP
------------------------
Omnitel 2400S+
Init = AT&FQ0V1E1X4S0=0S37=3&C1&D2\Q2\J0\V1|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Pace Linnet 2400
Init = ATQ0V1E1X1S0=0S50=1S57=0|
------------------------
Pace Linnet Quad
Init = ATC0E1Q0V1X4F0&A0&I1&K1&D2&C1&S1\Q0\N0S0=0\D0|
Speed = 4800
Disable EC = AT\P0|
Set MNP4 = AT\C4\P3|
Set MNP5 = AT\C5\P3|
Hardware MNP
------------------------
Pace Linnet 32
Init = ATC0E1Q0V1X4F0&A0&I1&K1&D2&C1&S1\Q0\N0S0=0\D0|
Speed = 38400
Disable EC = AT\P0|
Set MNP4 = AT\C4\P1|
Set MNP5 = AT\C5\P2|
Hardware MNP
------------------------
Pace Series 4 2400S
Init = ATQ0V1E1S0=0|
------------------------
Pace Ultralink V32
Init = AT&C1&D2Q0V1E1X1S7=60S0=0|
Speed = 19200
Disable EC = AT\P0|
Set MNP4 = AT\C4\P3|
Set MNP5 = AT\C5\P3|
Hardware MNP
------------------------
Penril Datacomm DLX V32
Init = ATX4E1Q0V1S0=0|
Speed = 19200
Disable EC = AT\N0|
Set MNP4 = AT\C4\N3|
Set MNP5 = AT\C5\N3|
Hardware MNP
------------------------
PerfectData EasyModem 144E/I
Init = ATB1E1N2Q0V1X4&C1&D2\N3\V1\Q3%C1|
Speed = 38400
Disable EC = AT\N0\V0\Q0|
Set MNP4 = AT\N3\V1\Q3%C0|
Set MNP5 = AT\N3\V1\Q3%C1|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------
Pract. Peripherals 14400 FXSA+FAX
Init = ATX4E1Q0V1W2S0=0N1&C1&D2&K3&Q5S36=7S46=2S48=7|
Speed = 38400
Disable EC = ATS36=3S46=0&Q6|
Set MNP4 = ATS36=7S46=0&Q5|
Set MNP5 = ATS36=7S46=2&Q5|
Failure = NO CARRIER|NO ANSWER|NO DIALTONE|BUSY|ERROR
Hardware MNP
------------------------
Pract. Peripherals PM 2400PPM Pocket Modem
Init = ATB1E1M4TQ0V1X4&C1|
Speed = 2400
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Software MNP
------------------------
Psion Dacom Goldcard (PCMCIA)
Init = ATB0F0E1V1X4&K3&C1&D2|
Speed = 19200
Disable EC = AT%C0\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C3\N3|
Hardware MNP
------------------------
Psion Dacom PDM 3/30
Init = ATB0F0X3E1V1&C1&D2|
Speed = 9600
Disable EC = AT%C0\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT&C3\N3|
Hardware MNP
------------------------
Psion Dacom PDM 4/40
Init = ATB0F0X4E1V1&C1&D2&K2&J2|
Speed = 19200
Disable EC = AT%C0\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT&C3\N3|
Hardware MNP
------------------------
Psion Dacom PDM 50/60
Init = ATB0F0E1V1X4&K3&C1&D2|
Speed = 57600
Disable EC = AT%C0\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C3\N3|
Hardware MNP
------------------------
QuickComm Spirit II V32bis & FAX
Init = AT&FE1Q0V1X4S0=0&D2&C1*F3|
Speed = 57600
Disable EC = AT*E0|
Set MNP4 = AT*E3|
Set MNP5 = AT*E9|
Hardware MNP
------------------------
Racal-Milgo Maxam IV
Init = ATE1Q0V1X4F0N1S0=0&I9&K1&L0&M0&D2&P0&C1&S1\Q0|
Speed = 4800
Disable EC = AT&E0|
Set MNP4 = AT\C4&E1|
Set MNP5 = AT\C5&E1|
Hardware MNP
------------------------
Racal-Milgo VI2422PA
Init = ATX9E1Q0V1&C1&D2S0=0*C1*F2*H0*K0*P1|
Disable EC = AT*E0|
------------------------
Sonix Volante V32.terbo
Init = AT&F0|
Speed = 115200
Disable EC = AT\N0%C0"H0|
Set MNP4 = AT\N3%C0"H0|
Set MNP5 = AT\N5%C1"H3|
Failure = ERROR|BUSY|NO CARRIER|NO DIALTONE|NO ANSWER
Hardware MNP
------------------------
SupraFAXModem v.32bis
Init = AT&F2S7=100S0=0|
Failure = NO CARRIER|BUSY|NO DIALTONE|NO ANSWER|ERROR
Speed = 38400
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
SVA/Universal FAXMODEM 9624P/H
Init = AT&FB0X3S0=0&C1&D2|
------------------------
Tandata TM512
Init = ATQ0V1E1X1S0=0|
------------------------
Tandata TM512 (DTI)
Init = |NP|~RESET|
Tone Dial = V23T|~
Pulse Dial = V23T|~
Dial Suffix = |
Connect = &WAT
AutoAnswerOn = |NP|~AA|
AutoAnswerOff= |NP|~RESET|
------------------------
Techpower TP96/24 Pocket FAX modem
Init = AT&FB0S0=0&C1&D2\V1\Q2|
Speed = 4800
Disable EC = AT\N0|
Set MNP4 = AT%C0\N5|
Set MNP5 = AT%C1\N7|
Hardware MNP
;NOTE: the B0 field shown in the above init string configures the modem
; for CCITT operation when running at 1200 bps. US users would likely
; need to change that to B1, for Bell 212A operation.
------------------------
Toshiba PCMCIA modem
Init = ATB0F0E1V1X4&K3&C1&D2|
Speed = 19200
Disable EC = AT%C0\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C3\N3|
Hardware MNP
------------------------
Toshiba TC2400 Internal
Init = ATQ0V1E1X2S0=0|
Speed = 4800
Disable EC = AT&E0|
Set MNP4 = AT&E1|
Set MNP5 = AT&E2|
Hardware MNP
------------------------
Twincom 96/42i Internal
Init = ATX4E1Q0V1&C1&D2&K3S0=0|
Speed = 19200
Disable EC = AT\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C1\N3|
Hardware MNP
------------------------
Twincom 14.4DF V32bis + FAX
Init = ATX4E1Q0V1W2S0=0N1&C1&D2&K3&Q5S48=7S36=4|
Speed = 38400
Disable EC = ATS36=1S46=136&Q6|
Set MNP4 = ATS46=136&Q5|
Set MNP5 = ATS46=138&Q5|
Hardware MNP
------------------------
USR Courier 2400e
Init = ATQ0V1E1X4S0=0&N0&R2&I0&H1&A1B2&B0|
Speed = 4800
Disable EC = AT&M0|
Set MNP4 = AT&M4&K0|
Set MNP5 = AT&M4&K1|
Hardware MNP
------------------------
USR Courier 2400 Plus
Init = ATQ0V1E1X2S0=0&I1B0F0&M0&C1&D2&K2&A0|
Speed = 4800
Disable EC = AT&E0|
Set MNP4 = AT&E1*E0|
Set MNP5 = AT&E1*E1|
Hardware MNP
------------------------
USR Courier HST
Init = AT&C1&D2Q0V1E1X4S0=0&B1&N0&R2&I0&H1&A3|
Speed = 19200
Disable EC = AT&M0|
Set MNP4 = AT&M4&K0|
Set MNP5 = AT&M4&K2|
Hardware MNP
------------------------
USR Courier HST Dual Standard
Init = AT&C1&D2Q0V1E1X4S0=0&B1&N0&R2&I0&H1&A3|
Speed = 38400
Disable EC = AT&M0|
Set MNP4 = AT&M4&K0|
Set MNP5 = AT&M4&K2|
Hardware MNP
------------------------
USR PCMCIA modem
Init = ATB0F0E1V1X4&K3&C1&D2|
Speed = 19200
Disable EC = AT%C0\N0|
Set MNP4 = AT%C0\N3|
Set MNP5 = AT%C3\N3|
Hardware MNP
------------------------
USR Sportster 14400 Fax Modem
Init = AT&C1&D2S0=0Q0V1&A3&B1&H1&I0&K3&R2|
Speed = 38400
Disable EC = AT&M0|
Set MNP4 = AT&M4&K0|
Set MNP5 = AT&M4&K2|
Hardware MNP
------------------------
Zenith Quad (Supersport Portable)
Init = ATQ0V1E1X1&C1&D2&I1S7=255|
Speed = 9600
Disable EC = AT\N0|
Set MNP4 = AT\N3|
Set MNP5 = AT\N3|
Hardware MNP
------------------------
Zoom 2400 V42bis
Init = ATX4E1Q0V1&C1&D2S0=0&K3W2|
Speed = 9600
Disable EC = AT&Q0|
Set MNP4 = ATS46=0&Q5|
Set MNP5 = ATS46=2&Q5|
Hardware MNP
------------------------
ZyXEL U-1496 and U-1496E
Init = ATB0E1M1N5Q0V1X5S0=0&B1&C1&D2&H3&M0&N0&P1&S1|
Speed = 38400
Disable EC = AT&K0|
Set MNP4 = AT&K1|
Set MNP5 = AT&K4|
Failure = NO CARRIER|ERROR|NO DIALTONE|BUSY|NO ANSWER
Hardware MNP
------------------------